FramingFloor framingLevel 22018 IRC

Stair opening in the second floor

Standing under a framed stair opening in a new two-story house and looking up at the second-floor framing. A 2x10 header runs across the opening between two 2x10 trimmer joists, and three tail joists run from the far side of the header in galvanized hangers at 16 inches on center. The header and both trimmers are single boards like the rest of the joists. A tape measure is hooked on one trimmer and pulled across the face of the header; the blade reads 62 where it meets the other trimmer and then hangs down to the tape case. Through the opening, the second-floor ceiling joists are visible above. S-P-FNo.2 KD-HT 24681012141618202224262830323436384042444648505254565860 62
Looking up through a stair opening in the second-floor framing

What's wrong here?

  1. The header and trimmers are single 2x10s across an opening wider than 4 ft; both must be doubled
  2. The header must hang from the trimmers in joist hangers once the opening is wider than 4 ft
  3. Tail joists may not hang from a header; they must bear on a wall
  4. Nothing. This installation is compliant
Start this drill
Show the answer and the code reference

The answer

The stair-opening header spans about 62 in. (5 ft 2 in.), but the header and both trimmer joists are single 2x10s. R502.10 requires both to be doubled when the header span exceeds 4 ft.

Correct choice: 1. The header and trimmers are single 2x10s across an opening wider than 4 ft; both must be doubled

At a floor opening the header picks up every tail joist and delivers that load to the trimmers at its ends, so each trimmer carries its own share of floor plus half the header. R502.10 allows a single header the same size as the joists only up to a 4 ft span, and a single trimmer only when that single header sits within 3 ft of the trimmer's bearing. Over 4 ft, the header and the trimmers must be doubled and big enough for the tail joists they carry. Here the tape reads about 62 in. between trimmers and the header carries three tail joists, but every member around the opening is a single 2x10. That gives you a bouncy, sagging stair edge and end nails carrying more than they should.

How to fix it

Add a second full-length trimmer on each side, bearing at both ends, and a second header ply, nailed together per the fastening schedule. Hangers at the header-to-trimmer connections are good practice at this span and become mandatory once the header span exceeds 6 ft.

Code reference

  • IRC 2018 R502.10 — Framing of openings

    Openings in floor framing must be framed with header and trimmer joists. A header spanning 4 ft or less may be a single member the same size as the joists, carried by a single trimmer if the header is within 3 ft of the trimmer's bearing. Where the header span exceeds 4 ft, the trimmers and header must be doubled and big enough for the tail joists they carry. Approved hangers are required at the header-to-trimmer connections when the header span exceeds 6 ft.

    Drills citing R502.10

2024 IRC:same rule and number. Summaries of 2024-based codes show the same R502.10 text: a single header up to 4 ft, doubled header and trimmers over 4 ft, approved hangers over 6 ft, and tail joists over 12 ft on framing anchors or 2x2 ledger strips. Not checked line by line against the printed 2024 IRC. Confidence: medium

Minnesota

MN adopts this rule as writtenConfidence: medium

Minnesota adopts the 2018 IRC with Minnesota amendments as the Minnesota Residential Code (Minn. Rules ch. 1309). No Minnesota amendment to R502.10 is known. DLI is adopting the 2024 IRC as the next edition; see the 2024 IRC note.

About the Minnesota Residential Code

Why the other choices are wrong

  • The header must hang from the trimmers in joist hangers once the opening is wider than 4 ft. R502.10 makes header-to-trimmer hangers mandatory only when the header spans more than 6 ft; this one spans about 5 ft 2 in. The 4 ft trigger is for doubling.
  • Tail joists may not hang from a header; they must bear on a wall. Tail joists normally frame into the header in hangers. R502.10 only adds a specific rule for tail joists over 12 ft long, which need framing anchors or 2x2 ledger strips.
  • Nothing. This installation is compliant. A single header and single trimmers are only allowed when the header spans 4 ft or less (R502.10); this header spans about 62 in.
Safety hazardLevel 2 · Journeyman#floor opening#header#trimmer#stair opening#tape measure

More in Floor framing